Digital Signal Converter for Encoder with SSI-Interface
SSI 9006
Successor of SSI 9002.
Highlights
- Input Synchronous Serial Interface SSI
- Up to 1 MHz clock frequency
- 4 alarm relays
- Optionally RS485 interface
- Master/slave mode
- Free scaling and zero definition
- Housing for DIN rail mounting EN 50 022
- Plug-in screw terminals
Technical Data
Parameters of Encoder
- Binary or gray code
- Singleturn/multiturn
- Direction of rotation
- Master/slave mode
SSI Signal Inputs
- Data input, receiver RS422/RS485
- Clock output, driver RS422/RS485
- Clock input, receiver RS422/RS485
Software Functions
- Programming of encoder data
- adjustable for encoder with 9–32 bit
- bit programming for fir-tree data format
- scaling factor
- zero point adjustment
- direction of rotation
- offset value
- incremental measurement
- display test and display hold (latch)
- MIN/MAX value detection
- auto-reset for MIN/MAX value
- setting of alarm points during measurement
Alarm Outputs
- 4 programmable alarm outputs with free allocation
- alarm point and hysteresis programmable
- relay function (high or low alarm)
- alarm response time (fall off and put on time)
- data source: direct encoder, MIN or MAX value
Power Supply
- 18 .. 36 V DC, isolated
- optional 12 V DC, isolated
- optional 5 V DC, isolated
Options
- interface RS 485