Progr. Process Instrument Model

PM 9000

Highlights

  • DIN rail mounting
  • Especially qualified for installation in flat wall case and terminal box
  • At standard a lot of measuring ranges for different sensors
  • Varied connections at digital IO's from PLC (also Mini-PLC)
  • 10 parameter sets for a quickly
    configuration
  • Measuring during parameter setup
  • Application as a nominal value
    transmitter
  • Analog Input Ranges
    • (16 bit, 5 measurements per sec, user configurable)
    • Measuring Ranges user scal-and tarable:

    • Voltage: ±20.00 V, ±2.000 V
      ±200.0 mV, ±20.00 mV
      Current: +/-20.00 mA,
      0/4 to 20.00 mA
      Angle potentiometer: 0 to 100.0 %
      Resistance: 0 to 1,000 kOhm
      DMS: 1,5/2/2,5/3/3,3 mV/V +/-100.0 % (4-wire)
    • Fixed Measuring Ranges:

    • Pt100: -200.0 to + 800.0 °C
      (2-, 4-wire)
      FeCuNi (J): -100 to +800 ° C
      NiCrNi (K): -100 to +1300 ° C
      PtRhPt (S): 0 to 1750 °C
      Temperature
      compensation:
      internal, constant or without
  • Digital Input Ranges
    • -input voltage 24 - 60 V, isolated
    • Counter (24 Bit, to scale):

    • Display range: +99999 to -9999
      Incremental: 1-, 2-, 4- fold to 2 kHz
      Impulse: max. 2 kHz, alternatively gate, direction, reset
    • Time Measuring

    • Frequency: 0.01 Hz to 10 kHz
      Time: to 9999.9 s
      Cycle: to 9999.9 s
      Pulse duration: to 9999.9 s
      Impulse/min 0 to 99999
      Impulse/h 0 to 99999
  • Special Function
    • Nominal value transmitter
  • Alarm Outputs
    • 2 alarms with solid-state relays
      (24 VDC, 200 mA, short-proof) supplying about the main power supply
    • Programmable functions:
      alarm point, hysteresis, switching characteristics, rise time - and fall time delay
      data source: direct input -, mean -, peak -, valley value
    • Direct connection to PLC
  • Analog Output
    • Free scaling, isolated, 14 Bit
    • Voltage: 0 to 10 V, max. 10 mA
    • Current: 0/4 to 20 mA, 500 Ohm burden
    • Data source: Direct input-, mean-, peak-, valley value
    • Error indication at current output
    • Sensor break: > 22 mA
    • Error: < 2 mA
to previous site to overview site to next site
PM 9000
to the offer form
zum Anwendungsplan to applicatation plan
     
 
The PM 9000 is provided with
10 parameter sets. Each parameter sets contains all adjustments
incl. 10 point linearisation. So the PM 9000 can be pre-programmed for 10 different areas of applications. If required the wished parameter set is be adjust and the instruments gets in the operation mode.
 
  Download catalogues, data sheets, manuals, in german, english and french Download: PDF-File catalogue german Download: PDF-File catalogue english Download: PDF-File datasheet german Download: PDF-File datasheet english Download: PDF-File manual german Download: PDF-File manual english
There is not available yet all
documents in each language
  • Synchron Serial Interface
    • Isolated
    • Connection of seperate displays with serial input
    • Connection to PLC resp. IO-cards
    • Measured value transmitting
    • Control of transfer rate via PLC
    • Minimum IO-expense at the PLC
  • Software Functions
    • User scaling
    • Adjustable digital filter of 1th order
    • Peak and valley detection
    • Userdefined linearization up to 10 points
    • Taring
    • Automatic reset of peak and valley detection
    • Display of temperature in °C, °F or K
    • Setting of parameters during measurement
  • Power Supply
    • 18-36 VDC, polarity reversal protection

 

to examples: Special Design to examples: Special Design to examples: Special Design
to examples: Special Design to examples: Special Design