Programmable Process Instrument
PM 9000
- Should only be used for spare parts requirements -
Highlights
- DIN rail mounting (35 mm / 32 mm G-rail)
- Especially qualified for installation in flat wall cases and terminal boxes
- At standard a lot of measuring ranges for different sensors
- Varied connections at digital IOs from PLC (also Mini-PLC)
- 10 parameter sets for a quick configuration
- Measuring during parameter setup
- Application as a nominal value transmitter
The PM 9000 is provided with 10 parameter sets. Each parameter set contains all adjustments including 10-point linearization. So the PM 9000 can be pre-programmed for 10 different areas of application. If required, the desired parameter set is selected and the instrument operates with these settings.
Technical Data
Analog Input Ranges
16 bit, 5 measurements per second, user scalable and tarable.
| Voltage | ±20.00 V, ±2.000 V, ±200.0 mV, ±20.00 mV |
|---|---|
| Current | ±20.00 mA, 0/4 to 20.00 mA |
| Angle potentiometer | 0 to 100.0 % |
| Resistance | 0 to 1,000 kOhm |
| DMS | 1.5/2/2.5/3/3.3 mV/V ±100.0 % (4-wire) |
| Pt100 | -200.0 to +800.0 °C (2-, 4-wire) |
| FeCuNi (J) | -100 to +800 °C |
| NiCrNi (K) | -100 to +1300 °C |
| PtRhPt (S) | 0 to 1750 °C |
| Temperature compensation | internal, constant or without |
Digital Input Ranges
| Input voltage | 24 - 60 V, isolated |
|---|---|
| Counter | 24 bit, scalable, display range +99999 to -9999 |
| – Incremental | 1-, 2-, 4-fold to 2 kHz |
| – Impulse | max. 2 kHz, alternatively gate, direction, reset |
| Frequency | 0.01 Hz to 10 kHz |
| Time | to 9999.9 s |
| Cycle | to 9999.9 s |
| Pulse duration | to 9999.9 s |
| Impulse/min | 0 to 99999 |
| Impulse/h | 0 to 99999 |
Special Function
- Nominal value transmitter
Alarm Outputs
- 2 alarms with solid-state relays (24 VDC, 200 mA, short-proof), supplied via the main power supply
- Programmable functions: alarm point, hysteresis, switching characteristics, rise time and fall time delay; data source: direct input, mean, peak, valley value
- Direct connection to PLC
Analog Output
- Free scaling, isolated, 14 bit
- Voltage: 0 to 10 V, max. 10 mA
- Current: 0/4 to 20 mA, 500 Ohm burden
- Data source: direct input, mean, peak, valley value
- Error indication at current output
- Sensor break: > 22 mA
- Error: < 2 mA
Synchronous Serial Interface
- Isolated
- Connection of separate displays with serial input
- Connection to PLC resp. IO cards
- Measured value transmitting
- Control of transfer rate via PLC
- Minimum IO expense at the PLC
Software Functions
- User scaling
- Adjustable digital filter of 1st order
- Peak and valley detection
- User-defined linearization up to 10 points
- Taring
- Automatic reset of peak and valley detection
- Display of temperature in °C, °F or K
- Undisturbed measuring during parameter setup
Power Supply
- 18 - 36 VDC, polarity reversal protection